Brand Name : Traumed
Place of Origin : China
MOQ : 1 Set
Price : Negotiated
Payment Terms : T/T, Western Union
Supply Ability : 100 Set/Sets per Month
Delivery Time : Within one week
Packaging Details : Strong Export carton case
Type : Ultrasonic First-Aid Systems
Instrument classifical : Class II
Pulse Measuring Range : 40bpm~235bpm
Blood Pressure : asuring Range: 20mmhg~240mmhg
Application : Operating Room/Ultrasonic Diagnose
Usage : Ultrasonic Diagnose
Function : Cardiac/ Obstetrics/ Gynecology/ Urology
Option : Ventricle Probe
Characteristics:
HY2850 can monitor variety of parameters such as the intracranial pressure,
blood pressure, blood oxygen saturation, pulse, per fusing pressure in encephalon,
pressure volume synchronously. It is either used in the neurosurgery of hospitals
or acted as the independent monitor of multi-parameter body symptom.
1. Monitoring the parameter such as intracranial pressure, cerebral perfusion pressure,
blood pressure, blood oxygen, pulse, pressure volume.
2. Imported blood oxygen saturation module and is suitable for the bad conditions such
as weak perfusion, low body temperature, serious Blood loss.
3. 10.4" TFT color display, Windows interface, operating in the touch screen.
4. 30 mins waveform replay in real-time, 72 hours waveform replay of intracranial
pressure tendency in real time.
5.255 groups data list sheet for blood pressure, blood oxygen saturation degree.
6. Store 30 zero-positions of fiber probe, auto-checking breakdown.
7. The printing output connector for waveform and data, alarming if exceeding the
parameter limit.
8. Intracranial pressure information transmitted by fiber, the temperature is not drifted.
Specification
Pulse measuring range | 40bpm~235bpm resolution: 1bpm error & le; 4bpm |
Blood oxygen saturation degree measuring range | 40~99%, resolution: 1%, error & le; 2% |
Intracranial pressure measuring range | -5kPa+20kPa |
Whole range measuring error | & le; 250Pa |
Zero point repetition | & le; 0.1kPa |
Blood pressure measuring range | 20mmHg~240mmHg |
Standard Configuration | Main unit epidural/subdural probe |
Option | Ventricle probe |
Features |
1. Pulse measuring range: 40bpm~235bpm resolution: 1bpm error & le; 4bpm |
2. Blood oxygen saturation degree measuring range: 40~99%, resolution: 1%, error & le; 2% |
3. Intracranial pressure measuring range: -5kPa+20kPa |
4. Whole range measuring error: & le; 250Pa |
5. Zero point repetition: & le; 0.1kPa |
6. Blood pressure measuring range: 20mmHg~240mmHg |
Standard Configuration: Main unit epidural/subdural probe |
Option: Ventricle probe |
![]() |
Portable ICP Monitor Neurosurgical Instruments Ultrasonic Diagnose For Hospital Images |